Overview of ..
This part of the Energy Efficiency Manual shows how to
lower the cost of air conditioning by limiting the entry of unwanted
sunlight into buildings through glazing. In warmer climates, reducing
the cooling load is the most important energy conservation measure
related to windows, skylights, and other glazing, formally grouped
under the heading of “fenestration.”.
Design of glazing should integrate the technical selection of windows
and skylights, atriums, and other glazing units with important architectural
issues, including view for the occupants, building appearance, daylighting,
and passive solar heating. Here you will learn to deal with all
these issues.
Ironically, the most important aspect of solar energy for many
buildings is keeping sunlight out. Since the advent of modern architecture,
with its vast expanses of bare glazing, designers have failed to
deal effectively with the enormous increase in cooling load that
is caused by such design. The air conditioning load caused by entry
of sunlight through glass typically is the largest cause of high
air conditioning cost in commercial buildings. In recent years,
electricity demand charges have risen steeply as utilities seek
to avoid building new power plants. Even in northern climates, heat
gain through glass may cause a large fraction of annual energy costs,
especially in heavily glazed buildings.
The heat content of direct sunlight is about 240 BTU per hour per
square foot (about 0.7 kilowatts per square meter), measured perpendicular
to the direction of the sunlight. Vertical glazing that is oriented
toward the east, west, or south receives roughly 1,000 BTU per square
foot (about 3 kilowatt-hours per square meter) per day in clear
weather. This figure does not vary much throughout the middle latitudes,
and it does not change much as the seasons change.
Many methods are available to reduce solar heat gain in virtually
all types of buildings. The most powerful methods are based on shading.
Exterior shading methods include parts of the building structure,
including balconies, eaves, soffits, window insets, and other architectural
features. External shading devices include awnings, louver materials,
horizontal shelves, and other types of shading in almost unlimited
configurations.
Interior shading devices include venetian blinds, roller shades,
draperies, louver blinds, diffusers, and a variety of other techniques
that are classed as “window treatment.” Some shading
devices are built into windows.
Plastic window films can be attached to existing windows to reduce
solar heat substantially, as well as providing other benefits, such
as breakage resistance. The ultimate shading technique is to reduce
the area of glazing, which can done in existing buildings as well
as new construction.
Windows, skylights, and other glazing should be selected to reduce
both heating and cooling energy consumption. Selection factors involving
the glass include the number of panes, the gap between panes, color,
low-emissivity (“low-E”) coatings, visible light transmission,
infrared heat transmission, and breakage resistance.
Selection factors involving frames for windows and skylights include
frame materials, the insulating properties of the frames, thermal
breaks, insulating gases, and seal reliability, frame durability,
and resistance to rain leakage. The ability to open windows is very
important in many applications. Openable windows are compared, including
sliding windows and double-hung windows, and various configurations
of hinged windows, including awning windows, casement windows, and
hopper windows.

|